- Mã sản phẩm: Model: EVAR-5 Line analyzer Orion Vietnam
- Giá: Liên hệ
- Lượt xem: 5812
- EVAR Line Monitor The Electrical Variable Analyzer Relay (EVAR) relay has been designed for the continuous monitoring of electrical parameters in medium or low-voltage 1-phase or 3-phase systems. It allows direct or remote monitoring of the system’s general conditions as it immediately signals any fault. EVAR can also be used to control the production process thanks to the programmable contacts suitable for various applications.
-
- Thông tin sản phẩm
- Bình luận
Applications
- Metering of distribution feeders, transformers, generators, capacitor banks and motors
- Commercial & industrial utility
- Flexible control for demand load shedding, power factor, etc
- Power quality analysis
Digital Measurement
- True RMS Phase & Ground Current
- True RMS Phase & Line Voltage
- Energy
- Positive & Negative Active power (kW) & Reactive power (kVAR)
- Last & Maximum Demand readings for:
- phase current (A)
- active power (kW)
- reactive power (kVAR)
- apparent power (kVA)
- Frequency (Hz)
- Voltage & Current Unbalance
- Voltage & Current harmonic analysis up to the 13th
- K-value measurement
- Event recorder
Communication
- Communication port: (1) RS232 and (2) RS485
- Remote programming of the setpoints
- Protocol used: Modbus RTU
- Ethernet comunication port (Modbus TCP/IP) - on request
https://www.orionitalia.com/line-monitor/evar
Signalling and Programming
- LCD & LED display indication
- Indication and storage of fault conditions and their values
- Indication on the system status:
- Normal
- Current fault
- Voltage fault
- Unbalance fault
- Power fault
- Power factor fault
- Demand fault
- THD fault
- Frequency fault
Protection and Functionality
- Phase Under & OverCurrent
- Ground OverCurrent
- Phase Under & OverVoltage
- Phase Sequence
- Current & Voltage total harmonic distortion (THD)
- Under & Over Frequency
- Positive & Negative active power
- Positive & Negative reactive power
- Voltage & Current Unbalance
- Power factor (leading or lagging)
- Demand readings for:
- phase current (A)
- active power (kW)
- reactive power (kVAR)
- apparent power (kVA)
Sản phẩm khác
Máy bơm cánh gạt đôi - VT6CC Double Vane Pumps - VT6CC code VT6CC-B25-B10-1R00-C1-00 Veljan Hydrauli
Giá: Liên hệ
Lưu lượng kế Code: RK1710-Air/N2-20L/min I RK1710-Air/N2-20L/min Flow meter Kofloc Vietnam
Giá: Liên hệ
Cảm biến phát hiện ngọn lửa Code: 95UVS4-1WINC InSight Series IV Flame Scanner Fireye Vietnam
Giá: Liên hệ
Cảm biến giám sát vị trí NJ20+U1+W (Part no: 36684S; U=20-253 VAC; I=500mA) P+F Việt Nam
Giá: Liên hệ
NS287-59E, Công tắc báo mức, Nakakita Seisakusho Vietnam, LEVEL SWITCH NS287-59E Nakakita Seisakusho
Giá: Liên hệ