- Mã sản phẩm: MSA 711 Fixed mounting-point left
- Giá: Liên hệ
- Lượt xem: 1697
- MSA 711 Fixed mounting-point left RSF ELEKTRONIK VIETNAM
-
- Thông tin sản phẩm
- Bình luận
- Mounting holes along the scale unit
- Fixed mounting-point left
- All other fastening elements flexible
- Max. measuring length: 3 040 mm (depends on grating pitch)
TECHNICAL DATA
Model |
Output signals |
System resolution |
Accuracy grades |
Grating period |
Integrated interpolation |
Max. velocity |
Max. output frequency |
Edge separation amin |
MSA 711.03 |
∿ 1 Vpp |
depending on external interpolation |
±3, ±5 µm/m |
20 µm |
-- |
2.0 m/s |
100 kHz |
-- |
MSA 711.01 |
∿ 1 Vpp |
depending on external interpolation |
±3, ±5 µm/m |
10 µm |
-- |
2.0 m/s |
200 kHz |
-- |
MSA 711.00 |
∿ 1 Vpp |
depending on external interpolation |
±2, ±3, ±5 µm/m |
8 µm |
-- |
2.0 m/s |
250 kHz |
-- |
MSA 711.23 |
TTL |
5.0 µm |
±3, ±5 µm/m |
20 µm |
times 1 |
2.0 m/s |
-- |
1.25 µs |
MSA 711.33 |
TTL |
2.5 µm |
±3, ±5 µm/m |
20 µm |
times 2 |
2.0 m/s |
-- |
625 ns |
MSA 711.63 |
TTL |
1.0 µm |
±3, ±5 µm/m |
20 µm |
times 5 |
2.0 m/s |
-- |
250 ns |
MSA 711.73 |
TTL |
0.5 µm |
±3, ±5 µm/m |
20 µm |
times 10 |
1.92 m/s |
-- |
250 ns |
MSA 711.61 |
TTLl |
0.5 µm |
±3, ±5 µm/m |
10 µm |
times 5 |
1.92 m/s |
-- |
250 ns |
MSA 711.71 |
TTL |
0.25 µm |
±3, ±5 µm/m |
10 µm |
times 10 |
0.96 m/s |
-- |
250 ns |
MSA 711.51 |
TTL |
0.1 µm |
±3, ±5 µm/m |
10 µm |
times 25 |
0.77 m/s |
-- |
125 ns |
MSA 711.81 |
TTL |
0.05 µm |
±3, ±5 µm/m |
10 µm |
times 50 |
0.38 m/s |
-- |
125 ns |
MSA 711.30 |
TTL |
1.0 µm |
±2, ±3, ±5 µm/m |
8 µm |
times 2 |
2.0 m/s |
-- |
250 ns |
MSA 711.70 |
TTL |
0.2 µm |
±2, ±3, ±5 µm/m |
8 µm |
times 10 |
0.77 m/s |
-- |
250 ns |
MSA 711.80 |
TTL |
0.04 µm |
±2, ±3, ±5 µm/m |
8 µm |
times 50 |
0.3 m/s |
-- |
125 ns |
MSA 711.90 |
TTL |
0.02 µm |
±2, ±3, ±5 µm/m |
8 µm |
times 100 |
0.15 m/s |
-- |
125 ns |
- Standard measuring length (ML): [mm]
- 70 to 1140 at 8 or 10 µm grating pitch
- 70 to 3040 at 20 µm grating pitch
- Scale unit:
- Glass scale (α≈8.5×10-6/K)
- Glass ceramic scale (α≈0×10-6/K)
- Reference marks:
- Distance-coded (K): after travelling max. 20 mm the absolute position is available
- Optional: one reference mark at any location; additional reference marks can be selected by distances of n x 50 mm
- Switch signals for special functions: according to factory default settings the moveable actuator magnets are placed at the beginning and at the end of measuring length
- Sealing (according EN 60529):
- Standard sealing lips: IP 53
- With DA 400: IP 64
- Permissible vibration: 100 m/s² (40 to 2000 Hz)
- Permissible shock: 200 m/s² (8 ms)
- Permissible temperature: -20 °C (storage), 0 °C to +50 °C (operation)
- Weight (approx.): 75 g + 0.57 g/mm (ML) + 50 g (reading head without cable)
- Standard cable: 3 m cable with Sub-D male connector 15-pin
- RoHS-conformity: the linear encoders MSA 711 comply with the guideline of the RoHS-directive 2011/65/EU and also with the delegated directive 2015/863/EU on the restriction of the