Tangas Flow HT/F

NDIR-Analyser TanGas Flow HT/F

Function

During the NDIR gas analysis (NDIR: non-dispersiveinfrared spectroscopy) the infrared radiation transmitted by a radiation source is conducted through a room (cuvette) filled with the gas to be analysed. The emerging radiation is then measured by a detector in a certain wavelength range. For the selection of this wavelength range non-dispersive elements such as optical filters are used instead of dispersive elements such as prisms or diffraction gratings. If the gas absorbs infrared radiation in this range, the gas concentration can be determined through the radiation reduction level, the spectral range of the infrared absorption (so e.g. CH4, CO2 and NH3, but not HE, N2, O2).

Application

This sensors are particularly used wherever precise measurements, high selectivity, insensitivity to toxic substances and unambiguous measurement results are of utmost importance. Measurement ranges for volume concentrations of ppm (ppb, if applicable) up to 10%.

Suitability

For measurements and warnings down to the LEL and for volume concentrations up to 100%.

Cross sensitivity

The selectivity depends on the type of gas and the optical design of the measurement equipment.

Assets
  • Suitable for the measurement of explosive gases and vapours in concentrations close to theLEL (Lower explosive limit)
  • Bypass measurement using a pump for measurementsin places that are hard to access
  • Analog output 4-20mA, two alarm thresholds and fault messages with 24V output for the alarm
  • Rugged NDIR analyser; with appropriate sample preparation also suitable for rugged industrial environments
  • Protection class IP 65 (Plug IP67), suitable for outdoor installation
  • Simple operation and calibration

Technical Data:
Medium:                        Methan (CH4)
Measuring Range:           0-100% LEL (0-5 Vol.%)
Precision:                       better than 2% FS
Reaction time (T90):      10 sec.
Operating temperature:   -20°C to +50°C (short time 60°C)
Humidity:                       0-95% RH (non condensing)
Power supply:                 24V DC
Power consumption:        6W
Analog output:                4-20 mA
IP Rating:                       IP65
Dimension:                     170 mm x 135 x 220mm
Weight:                          2.6 kg

Item number:               00-80-31647-A

https://www.tantronic.ch/index.php/en/2012-08-27-12-45-30/tangas-flow-ht-f 

Sản phẩm khác

CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
Hotline tư vấn: 0979 349 375 (Sales ) | 0948 708 042 (Sales Admin)
Zalo