  • The compact LPDT dew point meter is a fully functional instrument operated through a miniature custom LCD display and three push buttons, using the same user friendly interface of all Xentaur hygrometers. The analog output is linear to the engineering units selected for display and is user configurable. A weatherproof cap is available for outdoor NEMA 4X (IP65) applications.
  • Thông tin sản phẩm
  • Bình luận

TECHNICAL SPECIFICATIONS

Dewpoint Sensor Element Type: Hyper-Thin-Film high capacitance Al2 03

Dewpoint Range XTR-100 ............................... -100°C to +20°C (-148°F to +68°F)

XTR-65 ..................................-65°C to +20°C (-85°F to +68°F)

Capacitance .................................15nF to 200nF

Accuracy . .....................................±2°C (± 3.6°F) for -100°C to 0°C

Dewpoint .....................................±3°C (± 5.5°F)for 0°C to +20°C

Dewpoint Repeatability ...............................±0.5°C (±0.9°F)

Temperature range ....................-10°C to +70°C (+14°F to +158°F)

Sample Flow Range (linear vel. @ 1 atm.) ........Static to 100 m/s

Storage Temperature ...............-40°C to +80°C (-40°F to +176°F)

Calibration Method .................Field span check NIST/NPL traceable multipoint calibration

Temperature Measurement

The instrument measures the sample temperature with a precision integrated circuit sensor.

Electronics Input resolution .........................0.1°C(dp) Indicators ......................................3.5 digit LCD with custom legends

Engineering units ......................°C, °F, ppmv, LBS H2 O/mm scf, gm H2 O/M3

Controls ............................... 3 push buttons, all settings stored in EPROM

Output .................................Analog 4-20mA 

Alarms ..................................The 4-20 mA of the digital output may be used by an external device to operate relays

Isolation ............................... Sensor and case are isolated from the current loop and shunted with 33V transorbs Mechanical

Enclosure ............................Stainless steel (Weather proof cover optionally available)

Pressure operating range Standard: 34bar (500PSI)  Optional: 340 bar (5,000 PSI) 

Electrical connections ....2.1 mm power jack with retainer thread size 3/4”-16, 14mm x 12.5mm

Cable .................................... Two conductor cable

Power Requirements ......10 to 33 VDC, the instrument draws 4-20mA depending on measurement dewpoint 

Sản phẩm khác

Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Cty TNHH Kỹ Thuật Công Nghệ Và Dịch Vụ Tiên Phong
Hotline tư vấn: 0909 352 877 (Mr Nhật) - 0961 672 728 (Mr Thoát)
Zalo