| Product characteristics |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analog outputs: 1 |
| Factory setting |
hydrous coolants; water; media similar to water |
| Probe length L [mm] |
472 |
| Application |
| System |
gold-plated contacts |
| Media |
hydrous coolants; oils; oil-based media; water; media similar to water |
| Dielectric constant of the medium |
> 2 |
| Cannot be used for |
extremely conductive media; adhering media; granulates; bulk material; acids; alkali; food and electroplating industry |
| Maximum speed of the change of level [mm/s] |
200 |
| Tank pressure [bar] |
0.5; (when mounting with mounting accessories: E43001 - E43007, E43019) |
| Coolants |
| Medium temperature [°C] |
0...35; (with climate tube E43101: 35...60 °C) |
| Oil |
| Medium temperature [°C] |
0...70 |
| Medium temperature short time [°C] |
0...90; (< 1 h) |
| Water |
| Medium temperature [°C] |
0...35; (with climate tube E43101: 35...60 °C) |
| Electrical data |
| Operating voltage [V] |
18...30 DC |
| Current consumption [mA] |
< 50 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
< 3 |
| Inputs / outputs |
| Number of inputs and outputs |
Number of digital outputs: 1; Number of analog outputs: 1 |
| Outputs |
| Total number of outputs |
2 |
| Output signal |
switching signal; analog signal; IO-Link |
| Electrical design |
PNP/NPN |
| Number of digital outputs |
1 |
| Output function |
normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] |
2.5 |
| Permanent current rating of switching output DC [mA] |
200 |
| Number of analog outputs |
1 |
| Analog current output [mA] |
4...20, invertible |
| Max. load [Ω] |
500 |
| Analog voltage output [V] |
0...10, invertible |
| Min. load resistance [Ω] |
2000 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
thermal, pulsed |
| Overload protection |
yes |
| Measuring/setting range |
| Factory setting |
hydrous coolants; water; media similar to water |
| Probe length L [mm] |
472 |
| Active range A [mm] |
390 |
| Inactive range I1 / I2 [mm] |
60 / 22 |
| Setting range |
| Set point SP [mm] |
35...390 |
| Reset point rP [mm] |
30...385 |
| Hysteresis [mm] |
5 |
| Reference point OP [mm] |
139 - 163 - 188 - 212 - 236 - 261 - 285 - 310 - 334 - 358 - 383 - 407 - OFF |
| Hysteresis, OP [mm] |
3 |
| Accuracy / deviations |
| Measuring error [% of the final value] |
± 5 |
| Repeatability |
± 2 |
| Resolution [mm] |
5 |
| Zero signal (voltage) [V] |
0 |
| Zero signal (current) [mA] |
4.0 |
| Full signal (voltage) [V] |
10 |
| Full signal (current) [mA] |
20 |
| Software / programming |
| Parameter setting options |
hysteresis / window; normally open / closed; switching logic; current/voltage output; SP/rP position; adjustment OP; medium selection; offset setting; switch-on/switch-off delay |
| Interfaces |
| Communication interface |
IO-Link |
| Transmission type |
COM2 (38,4 kBaud) |
| IO-Link revision |
1.1 |
| SDCI standard |
IEC 61131-9 |
| IO-Link device ID |
0x00028A |
| Profiles |
Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis |
| SIO mode |
yes |
| Required master port class |
A |
| Process data analogue |
2 |
| Process data binary |
1 |
| Min. process cycle time [ms] |
3.2 |
| Operating conditions |
| Ambient temperature [°C] |
0...60 |
| Storage temperature [°C] |
-25...80 |
| Protection |
IP 67 |