|
Pos |
Code and Description |
Manu |
Q’ty |
|
1
|
01-90-34540-A Programming TanGas Flow 2016net (Sensor 1 KKS CYQ01CQ212) |
Tantronic |
1 |
|
2
|
00-90-35000-A TanGas Flow 2016net Analyser for the measurement of explosive gas with pump by-pass process. Indication of the gas concentration and the alarm status. The activation of the integrated solenoid valve block for the automatic zero point and/or sensitivity calibration. The system can be adapted to all customized requirements simply with the password protected menu structure. The configuration of the alarm organization is very simply realized with the integrated alarm matrix. Technical Data: Type of device: TanGas Flow 2016net Power Supply: 24V DC Max. Consumption: 25W Temperature Range: -20°C to +50°C (short time 60°C) Analog-Output: 1x4-20mA (max. 250 ohms) Digital-Output: 4 Logic Signal for Alarm 1 to 4 1 Logic Signal for Sensor Fault 1 Logic Signal for Calibration Mode * 1 Logic Signal for Calibration Status 1 Logic Signal for Maintenance Alarm Network: TCP/IP RS232C, CAN Bus(in preparation) Remote Control: with TCP/IP Data Pick Out: with FTP Event Recorder: for max. 4000 Events Temperature Recorder: for max. 4000 Events * Note dew point of sampling Technical Data IR-Sensor: Type of Gas: Methane CH4 Measuring Principle: ND-Infrared Detector Measuring Range: 0-100% LEL Reaction Time T90: < 10 seconds Accuracy: 2% FS Stability: < ± 1% / Month Zero-Drift: < ± 1% / Month Temperature Range: -20°C to +50°C (short time 60°C) Relative Humidity: < 99% RH Warm up Time: 1 hour Electrical Connections: Power Supply and Data Interface: 4 pole Plug TCP/IP: 1x RJ45 Remote maintenance:: with Web Interface Pneumatic Connections: Push Plug-In: 2x6mm Dimensions: Housing Type: Wall Mounting Unit Aluminum Painting: Powder Coating RAL 7035/5002 Type of Protection: IP65 |
Tantronic 100% Switzerland Origin |
1 |
|
3
|
00-00-30989-A Certificate of Origin used by Chamber of Commerce |
1 |
|
|
4
|
00-00-34535-A Manual TAN-1104 (CD) |
Tantronic 100% Switzerland Origin |
1 |
|
5
|
00-00-32095-A Packaging, transport and insurance |
1 |
- Ball valve, 760003012, 760003012 Valpres, Valpres/ Valbia Vietnam (02.11.2021)
- Ball valve, 760003010, 760003010 Valpres, Valpres/ Valbia Vietnam (02.11.2021)
- Ball valve, 76000308, 76000308 Valpres, Valpres/ Valbia Vietnam (02.11.2021)
- Ball valve, 76000307, 76000307 Valpres, Valpres/ Valbia Vietnam (02.11.2021)
- Ball valve, 76000306, 76000306 Valpres, Valpres/ Valbia Vietnam (02.11.2021)
- Động cơ rung, BLZ/50-55/4/01/50, Invicta Vibrators Vietnam (30.10.2021)
- Bộ điều khiển PID, 8120200220, 8120200220 NOVUS Automation Vietnam, NOVUS Automation Vietnam (29.10.2021)
- Bộ điều khiển PID, 8120200224, 8120200224 NOVUS Automation Vietnam, NOVUS Automation Vietnam (29.10.2021)
- Máy đo mức âm thanh, TLX-120AP1 , TLX-120AP1 Towa Seiden, Towa Seiden Việt Nam (29.10.2021)
- SML-ME/8, SML-ME, SML-WME, SML-WME/8, Sensormate Vietnam, Đại lý Sensormate Vietnam (26.10.2021)





E-mail: sale09@ltdautomation.com.vn




