Ngày đăng: 10:12 AM, 25/11/2020
| GS150/GS150LE Process Imaging System for Glass Processing | ||
| RAYTGS150G5R1 | specifies a Glass System with a low temperature 5µm linesscanner with RJ-45 type cable and 1024 maxmum data points per scan line. | |
| RAYTGS150G5R0 | specifies a Glass System with a low temperature 5µm linesscanner with RJ-45 type cable and 1024 maxmum data points per scan line. | |
| UPGRADES | ||
| RAYTGS150LEUPGRADE | The GS150LE system was developed specifically to monitor glass which has been coated on one side with a low-emissivity coating. Includes specialized MI3 sensor and GS150LE software, air-purge jacket, PC connection Kit | |
| OPTIONS | ||
| XXXTMP150CERT | Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item) | |
| XXXTMP50ACRMB | Adjustable Rugged Mounting Base (includes scanner mounting plate) | |
| XXXHSFIC1 | High Speed Fiber-Optic/RJ45 Converter (1 Channel) | |
| XXXHSFIC2 | High Speed Fiber-Optic/RJ45 Converter (4 Channel) | |
| XXXHSFICBOX | Housing, Fiber optic/RJ-45 converter and power supply | |
| SVCOSSAPKG | On-site Start-up and Commissioning Service (North America Only) | |
| ES150 Process Imaging System for Film and Flat Sheet Extrusion or Continuous Web Processes | ||
| RAYTES150-LT | ES150 System with MP150LT 20 to 350°C (68 to 572°F), 3 to 5 microns | |
| RAYTES150-MT | ES150 System with MP150MT, 100 to 800°C (212 to 1472°F), 3.9 microns | |
| RAYTES150-G5 | ES150 System with MP150G5, 100 to 950°C (212 to 1742°F), 5 microns | |
| RAYTES150-P30 | ES150 System with MP150P30, 30 to 250°C (86 to 482°F), 3.43 microns | |
| RAYTES150-P31 | ES150 System with MP150P31, 100 to 350°C (212 to 662°F), 3.43 microns | |
| RAYTES150-1M | ES150 System with MP1501M, 600 to 1200°C (1112 to 2192°F), 1 micron | |
| RAYTES150-2M | ES150 System with MP1502M, 400 to 950°C (752 to 1742°F), 1.6 micron | |
| OPTIONS | ||
| XXXTMP150CERT | Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item) | |
| XXXTMP50ACRMB | Adjustable Rugged Mounting Base (includes scanner mounting plate) | |
| XXXHSFIC1 | High Speed Fiber-Optic/RJ45 Converter (1 Channel) | |
| XXXHSFIC2 | High Speed Fiber-Optic/RJ45 Converter (4 Channel) | |
| XXXHSFICBOX | Housing, Fiber optic/RJ-45 converter and power supply | |
| SVCOSSAPKG | On-site Start-up and Commissioning Service (North America Only) | |
| EC150 Process Imaging System for Film and Flat Sheet Extrusion or Continuous Web Processes | ||
| RAYTEC150-P30-R | EC150 System with MP150P30, 30 to 250°C (86 to 482°F), 3.43 microns | |
| RAYTEC150-P31-R | EC150 System with MP150P31, 100 to 350°C (212 to 662°F), 3.43 microns | |
| OPTIONS | ||
| XXXTMP150CERT | Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item) | |
| XXXTMP50ACRMB | Adjustable Rugged Mounting Base (includes scanner mounting plate) | |
| XXXHSFIC1 | High Speed Fiber-Optic/RJ45 Converter (1 Channel) | |
| XXXHSFIC2 | High Speed Fiber-Optic/RJ45 Converter (4 Channel) | |
| XXXHSFICBOX | Housing, Fiber optic/RJ-45 converter and power supply | |
| SVCOSSAPKG | On-site Start-up and Commissioning Service (North America Only) | |
| CS210 Infrared Linescanning System for Rotary Kilns | ||
| RAYTCS211R1 | CS211 Rotating Kiln System (Single Scanner) Linescanner MP150HR Protective Housing XXXSYSPHSS, stainless steel Position Indicator with junction box (XXXSYSSECPI) System Connection Box (field) CS210CONBOX Fibre Optic Converter Housing XXXHSFICBOX (control room DataTemp CS Software Documentation |
|
| RAYTCS212R1 | CS212 Rotating Kiln System (Dual Scanner) 2 Protective Housings XXXSYSPHSS, stainless steel Position indicator with junction box (XXXSYSSECPI) 2 System Connection Boxes (field) CS210CONBOX Fibre Optic Converter Housing XXXHSFICBOX (control room) DataTemp CS Software Documentation |
|
| RAYTCS213R1 | CS213 Rotating Kiln System (Triple Scanner) 3 Linescanners MP150HR 3 Protective Housings XXXSYSPHSS, stainless steel Position indicator with junction box (XXXSYSSECPI) 3 System Connection Boxes (field) CS210CONBOX Fibre Optic Converter Housing XXXHSFICBOX (control room) DataTemp CS Software Documentation |
|
| RAYTCS214R1 | CS214 Rotating Kiln System (Quad Scanner) 4 Linescanners MP150HR 4 Protective Housings XXXSYSPHSS, stainless steel Position indicator with junction box (XXXSYSSECPI) 4 System Connection Boxes (field) CS210CONBOX Fibre Optic Converter Housing XXXHSFICBOX (control room) DataTemp CS Software Documentation |
|
| RAYCS210EXT | CS21x Extension KIT Maximum Extension up to a four Scanner System 1 Scanner RAYTMP150HRR1 1 Stainless Steel protective housing incl. Mounting Base XXXSYSPHSS 1 System Connection Box XXXCS210CONBOX Scanner Cable Set LT New License file (Serial number from all existing scanners needed with P.O.) |
|
| ACCESSORIES | ||
| XXXSYSCS210CON | Serial Ethernet Converter | |
| Please note: Always necessary to connect with following components:XXXTCSLRM210, FAN Control Hardware, XXXTCS200BZ and XXXTCS200SM | ||
| XXXCS210CONBOX | CS210CONBOX,CS210 SYSTEM CONNECTION BOX | |
| XXXCS210ENCON | Endurance Connection Box | |
| XXXSYS16DA* | RS485 Remote Controller with 16 Digital-Outputs | |
| XXXSYS7RA | 7-Channel Relays Output Modul | |
| XXXTCS210BZ | Burning Zone Monitoring: Endurance Connection Box Endurance Ratio Pyrometer, 600 to 1800°C 15 m High Temperature Cable ThermoJacket Housing for E-TJ1 Blast Gate Assembly with Quartz Window 30 cm sighting tube, stainless steel Adjustable Pipe Adapter assembly Adjustable Mounting Base for Thermojacket Air Flow/Pressure Regulator Assembly |
|
| XXXTCS200SM | Shadow Monitoring: consists of MI Connection Box, MIH Sensor -40 to 600°C, 8 m high temperature cable, Air Purge Jacket, stainless steel, Adjustable Mounting Bracket. | |
| XXXTCSLRM210 | Live Ring Migration for CS210 System, complete with LRM Remote Controller & 3 position indicators | |
| XXXSYSLDM | Laser distance meter | |
| XXXPi20FO1 | Fiber Optic Cable 150 m | |
| XXXPi20FO2 | Fiber Optic Cable 300 m | |
| SVCOSSAPKG | On-site Start-up and Commissioning Service (Item # 2509605/North America only) | |
| XXXSYS4AA | Analog Output Module (4 channels, mA or V) | |
| XXXSYS485CV | RS232/RS485 Converter (required for Output Modules) | |
Bài viết khác
- Safety relay, ESM-BA201, 085610, Euchner Vietnam, Đại lý Euchner Việt Nam (14.01.2022)
- Actuator, A-B-A1-A1-161642, 161642, Euchner Vietnam, Đại lý Euchner Vietnam (14.01.2022)
- Safety switch sensing, CTM-LBI-BR-U-AZ-SA-161638, 161638, CTM-LBI-BR-U-AZ-SA Euchner, Đại lý Euchner (14.01.2022)
- STA3A-4131A024M SAFETY SENSING Euchner Vietnam (10.01.2022)
- List hàng giá tốt 30-12-2021 (10.01.2022)
- List hàng giá tốt 29-12-2021 (10.01.2022)
- List hàng giá tốt 28-12-2021 (10.01.2022)
- List hàng giá tốt 27-12-2021 (10.01.2022)
- Máy thổi kênh bên FPZ, SK75MS00+0041, PTC Việt Nam, Đại lý chính thức FPZ S.p.A. tại Việt Nam (14.12.2021)
- Gas Sensor Module, AG01E, CWV2, GWNVXX, Veris Vietnam, Đại lý Veris Việt Nam (10.12.2021)





E-mail: sale09@ltdautomation.com.vn