Ngày đăng: 10:09 AM, 25/11/2020
| Raytek RAYMI310LTSCB8 Infrared Temperature Sensor with 8m Cable, 10:1 Optics, -40 to 600°C (-40 to 1112°F) | ||
| Raytek RAYMI310LTSCB15 Infrared Temperature Sensor with 15m Cable, 10:1 Optics, -40 to 600°C (-40 to 1112°F) | ||
| Raytek RAYMI310LTSCB3 Infrared Temperature Sensor with 3m Cable, 10:1 Optics, -40 to 600°C (-40 to 1112°F) | ||
| Raytek RAYMI302LTSCB30 Infrared Temperature Sensor with 30m Cable, 2:1 Optics, -40 to 600°C (-40 to 1112°F) | ||
| XXXMI3CERT | Calibration is traceable to the International System of Units (SI), through National Metrological Institutes such as NIST (order as a separate line item) | |
| SYSTEM EXPANSION ACCESSORIES | ||
| XXXMI3CONNBOX | Multi-channel sensor interface box for MI3 and MI3M series communications modules. Includes 8 sets of field wiring terminals wired in parallel to one 5 meter (16.4') cable to connect to MI3 or MI3M communications module. | |
| XXXUSB485 | USB to RS232/422/485 converter | |
| RAYMI3COMMI | Installation of MI3 sensing head with MI3/MI3M communications box | |
| MECHANICAL ACCESSORIES | ||
| XXXMIACMN | Sensing head mounting nuts - 5 pieces | |
| XXXMIACFB | Sensing head fixed mounting bracket | |
| XXXMIACAB | Sensing head adjustable mounting bracket | |
| XXXMIACAJ | Air purge jacket (no cooling) - For use in ambient temperatures <200°C (<392°F). | |
| XXXMIACAJI | Air purge jacket (no cooling) - installed, for MI3xxLTH only possible option - For use in ambient temperatures <200°C (<392°F). | |
| XXXMIACCJ | Air cooling and purging system with .8m (2.8') insulated air hose. For use in ambient temperatures <200°C (<392°F). Not compatible with MI3LTH. | |
| XXXMIACCJ1 | Air cooling and purging system with 2.8m (9.2') insulated air hose. For use in ambient temperatures <200°C (<392°F). Not compatible with MI3LTH. | |
| XXXMIACRAJ1 | Right angle mirror with air purging systems. For use in ambient temperatures <200°C (<392°F). Not compatible with MI3LTH. | |
| XXXMIACRAJ | Right angle mirror for use with air cooling and purging systems. For use in ambient temperatures <200°C (<392°F). Not compatible with MI3LTH. | |
| XXXMIACPW | Zinc Sulfide protective window for MI sensors. Not for use with air purging or air cooling systems. | |
| XXXMI3ACPWP | Polymer protective window for MI3 sensors. Not for use with air purging or air cooling systems. | |
| XXXMI3ACCFL | MI3 Close Focus Lens Accessory, 10mm focus distance. LT models only. | |
| D82MIACAJ | Stainless steel air purge jacket (no cooling) - For use in ambient temperatures <200°C (<392°F) | |
| XXXUSBCABLE | USB cable assembly, 4 COND, USB-A(M), USB-MINI-B(M), Shielded, 2M | |
| MI3 1M, 2M Series | ||
| STANDARD MI3 HIGH TEMPERATURE SENSING HEADS: 1M AND 2M SENSING HEADS ARE RATED FOR A MAXIMUM AMBIENT TEMPERATURE OF 120°C (<250°F) | ||
| RAYMI31001MSF1 | 500 to 1,800°C (932 to 3,272°F), 1 µm, 100:1 D:S, 200mm Focus, 10 msec, 1m cable | |
| RAYMI31001MSF3 | 500 to 1,800°C (932 to 3,272°F), 1 µm, 100:1 D:S, 2,200mm Focus, 10 msec, 1m cable | |
| RAYMI31002MSF1 | 250 to 1,400°C (482 to 2,552°F), 1.6 µm, 100:1 D:S, 200mm Focus, 10 msec, 1m cable | |
| RAYMI31002MSF3 | 250 to 1,400°C (482 to 2,552°F), 1.6 µm, 100:1 D:S, 2,200mm Focus, 10 msec, 1m cable | |
| 1M and 2M sensing heads are rated for a maximum ambient temperature of 120°C (<250°F) | ||
| SYSTEM EXPANSION ACCESSORIES | ||
| XXXMI3CONNBOX | Multi-channel sensor interface box for MI3 and MI3M series communications modules. Includes 8 sets of field wiring terminals wired in parallel to one 5 meter (16.4') cable to connect to MI3 or MI3M communications module. | |
| XXXUSBCABLE | USB cable assembly, 4 COND, USB-A(M), USB-MINI-B(M), Shielded, 2M | |
| XXXUSB485 | USB to RS232/422/485 converter | |
| XXXSYSPS | 24VDC power supply (100/240),1.3 amps | |
| MECHANICAL ACCESSORIES | ||
| XXXMI3100MN | Stainless steel mounting nuts (2) -metric threads | |
| XXXMI3100FB | Stainless Steel Fixed Bracket | |
| XXXMI3100ADJB | Stainless Steel Adjustable Bracket | |
| XXXMI3100AP | Metric Air Purge Collar | |
| XXXMI3100RAM | Right Angle Mirror, metric thread | |
Bài viết khác
- Đại lý Lemis Việt Nam, Lemis Vietnam, DC-41, DC-42, DC-51, DC-52, VC-30 (06.08.2021)
- Đại lý Lemis Việt Nam, Lemis Vietnam, LPGDi Ex, DenDi, DM-300, VDM-300, DM-250.5 (06.08.2021)
- Đại lý Lemis Việt Nam, Lemis Vietnam, VDC-30, DUTI-454, DC-30, VDM-250.1N, VDM-250.2N (06.08.2021)
- Đại lý Lemis Việt Nam, Lemis Vietnam, DUTI-254, MDM-40, DLG-400, DM-250.1N, DUTI-254, DM-250.4 (06.08.2021)
- Đại lý Lemis Việt Nam, Lemis Vietnam, DC-40, DC-42, DC-50, DC-52, DC-60 (06.08.2021)
- Elmeko Vietnam, đại lý Elmeko, LMR-330-MG, LMT-615-MG, LMT-570-MGW, LMT-330-MG, DEM 12 MS (06.08.2021)
- Elmeko Vietnam, đại lý Elmeko, LMM-880-MW, LMM-630-MW, LMM-370-MW, LMR-840-MG, LMR-580-MG (06.08.2021)
- Elmeko Vietnam, đại lý Elmeko, LLX-800-S, LLX-800-BW, LLX-800-SW, LE-982-106, LE-982-103 (06.08.2021)
- Elmeko Vietnam, đại lý Elmeko, LLX-400-BWU, LLX-400-BWX, LLX-400-SWU, LLX-400-SWX, LLX-800-B (06.08.2021)
- Elmeko Vietnam, đại lý Elmeko, LLX-400-SV, LLX-400-BM, LLX-400-BW, LLX-400-SW, LLX-400-BWM (06.08.2021)





E-mail: sale09@ltdautomation.com.vn




