Mechanical values and environment
Housing material | |
Switch head cover | Die-cast zinc |
Safety switch housing | Fiber glass reinforced thermoplastic |
Weight | |
Net | 0,42 kg |
Ambient temperature | |
At UB = 24V DC | -20 ... +55 °C |
Degree of protection | IP67/IP69/IP69K |
Resilience to vibration | In acc. with EN IEC 60947-5-3 |
Mechanical life | 1 x 106 |
Installation orientation | Any |
Ready delay | max.1 s |
Switching frequency | max.0,5 Hz |
Connection | 1 plug connector M12, 8-pin |
Approach speed | max.20 m/min |
Guard locking principle | Closed-circuit current principle |
Locking force Fmax | 3900 N |
Locking force FZh | 3000 N |
Retention force | 20 N |
Extraction force | 20 N |
Actuating force | 10 N |
Overtravel | 5 mm |
Electrical connection ratings
Test-pulse interval | min.100 ms |
Test pulses | max.0,3 ms |
Operating voltage DC | |
UUB | 24 V DC -15% ... 15% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Current consumption | |
IUB | 40 mA |
IIMP | 400 mA |
Utilization category according to EN 60947-5-2 | |
DC-13 | 24V 150mA |
Solenoid operating voltage DC | |
UIMP | 24 V DC -15% ... +10% Reverse polarity protected, regulated, residual ripple < 5%, PELV |
Fusing | |
External (solenoid operating voltage IMP) | 0,5 ... 8 A |
External (operating voltage UB) | 0,25 ... 8 A |
Rated insulation voltage Ui | 50 V |
Rated impulse withstand voltage Uimp | 0,5 kV |
Power consumption | 6 W |
EMC protection requirements | In acc. with EN IEC 60947-5-3 |
Solenoid duty cycle | 100 % |
Degree of contamination (external, according to EN 60947-1) | 3 |
Safety class | |
EN IEC 61140 | III |
Switching load | |
According to UL | 24V DC, class 2 |
Safety outputs FO1A / FO1B | |
Type of output | 2 semiconductor outputs, p-switching, short circuit-proof |
Switching current | |
Per safety output FO1A / FO1B | 1 ... 150 mA |
Output voltage | |
HIGH U(FO1A) / U(FO1B) | UB-1,5 ... UB V DC |
LOW U(FO1A) / U(FO1B) | 0 ... 1 V DC |
Off-state current Ir | max.0,25 mA |
Turn-on time | max.400 ms |
Discrepancy time | |
Both safety outputs | max.10 ms In acc. with EN IEC 60947-5-3 |
Monitoring output OD | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Monitoring output OI | |
Type of output | p-switching, short circuit-proof |
Switching current | 1 ... 50 mA |
Output voltage | 0,8xUB ... UB V DC |
Work area
Repeat accuracy R | |
According to EN 60947-5-2 | 10 % |
Other
For the approval according to UL the following applies | Operation only with UL class 2 power supply, or equivalent measures see operating instructions |
Reliability values according to EN ISO 13849-1
Performance Level | PL e |
Category | 4 |
PFHD | 4.1 x 10 -9 |
Mission time | 20 y |
Sản phẩm khác
Code: 161559 Description: MGBS-P-L1HE-AP-U-L-SA-161559 Locking module with handle module Euchner
Giá: Liên hệ
Raytek RAYCMLTK3M Infrared Temperature Sensor with RS232, Type K Output, 3m Cable, 18Mx1 Thread Rayt
Giá: Liên hệ
TD6000-401U Fairchild Model T6000 Compact Electro-Pneumatic I/P, E/P Transducer FAIRCHILD Vietnam
Giá: Liên hệ
41C.A.2.M2.WP, 41A.A.2.2M2.WP, Đại lý OFFICINE OROBICHE Việt Nam, Phao điện đo mức nước OFFICINE ORO
Giá: Liên hệ