Measuring range |
0.15 m ... 100 m, on reflective tape "Diamond Grade" |
Target |
Reflector |
Resolution |
0.1 mm, 0.125 mm, 1 mm, 10 mm, 100 mm |
Repeatability |
0.5 mm 1) |
Accuracy |
± 2 mm 2) |
Response time |
2 ms |
Measurement cycle time |
1 ms 3) |
Output time |
1 ms, measurement cycle synchronous to PLC request |
Light source |
Laser, red 4)
visible red light |
Laser class |
2, complies with 21 CFR 1040.10 and 1040.11 except for the tolerance according to “Laser Notice No. 50” from June 24, 2007 (IEC 60825-1:2014, EN 60825-1:2014) |
Typ. light spot size (distance) |
5 mm + (2 mm x distance in m) |
Max. movement speed |
15 m/s |
Acceleration (max.) |
≤ 15 m/s² |