Đ/c: Số 21, Đường Số 12, Khu Đô Thị Vạn Phúc, P. Hiệp Bình Phước, Q.Thủ Đức, Tp HCM
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
  • Mã sản phẩm: MG6028 Fast Tuned Magnetron E2V Vietnam, Đại lý E2V Vietnam
  • Giá: Liên hệ
  • Lượt xem: 4022
  • Thông tin sản phẩm
  • Bình luận

MG6028 Fast Tuned Magnetron E2V Vietnam, Đại lý E2V Vietnam 

100% UK Origin E2V Vietnam Code: MG6028
Fast Tuned Magnetron

VE2116 is mainly used for mid-power linear accelerators, which is designed and made by Beijing Vacuum Electron Research Institute. It can replace the MG6028、 MG6370 pulse Magnetron perfectly

Health and Safety Hazards The magnetrons are safe to handle and operate, provided that the relevant precautions stated herein are observed. We do not accept responsibility for damage or injury resulting from the use of electronic devices we produces. Equipment manufacturers and users must ensure that adequate precautions are taken. Appropriate warning labels and notices must be provided on equipment incorporating our devices and in operating manuals. High Voltage Equipment must be designed so that personnel cannot come into contact with high voltage circuits. All high voltage circuits and terminals must be enclosed and fail-safe interlock switches must be fitted to disconnect the primary power supply and discharge all high voltage capacitors and other stored charges before allowing operation with access doors open. RF Radiation Personnel must not be exposed to excessive RF radiation. All RF connectors must be correctly fitted before operation so that no leakage of RF energy can occur and the RF output must be coupled efficiently to the load. It is particularly dangerous to look into open waveguide or coaxial feeders while the device is energized. Screening of the cathode sidearm of high power magnetrons may be necessary. X-Ray Radiation High voltage magnetrons emit a significant intensity of X-rays not only from the cathode sidearm but also from the output waveguide. These rays can constitute a health hazard unless adequate shielding for X-ray radiation is provided. This is a characteristic of all magnetrons and the X-rays emitted correspond to a voltage much higher than that of the anode. Toxic Material This device contains fluorinated elastomers. If exposed to temperatures above 400℃ these degrade and form hydrofluoric acid. This is a serious health hazard if skin contact occurs. Access to these components is not possible unless the device is damaged or dismantled. 

Sản phẩm khác

CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
CTY TNHH DỊCH VỤ KỸ THUẬT TỰ ĐỘNG HÓA LÂM TUỆ ĐỨC
Hotline tư vấn: 0979 349 375 (Sales ) | 0948 708 042 (Sales Admin)
Zalo