- Mã sản phẩm: Model: FXAOM01AD Analog Output module
- Giá: Liên hệ
- Lượt xem: 6375
- Model: FXAOM01AD Analog Output module Mitsubishi Hitachi Power System Việt Nam * Number of outputs: 8 (4~20mA/0~20mA) * Load resistance : 0~550Ω * Duplicated correspondence * FLEX I/OTM / ControlNetTM LAN compatible
-
- Thông tin sản phẩm
- Bình luận
The following are links to the functions and specifications of Analog Modules.
Category | Type | Specification |
---|---|---|
Analog Input | FXAIM01 | 4 - 20mA inputs: 8 |
FXAIM01C | 4 - 20mA inputs: 8 AD Converter duplicated |
|
FXAIM02 | Transmitter inputs: 8 | |
FXAIM02C | Transmitter inputs: 8 AD converter duplicated |
|
FXAIM03 | 0-5VDC / 1-5VDC inputs: 8 | |
FXAIM03C | 0-5VDC / 1-5VDC inputs: 8 AD converter duplicated |
|
FXAIM04A-UP | Thermocouple inputs: 7 T, R, J, K, E type correspondence -16 - 80mV full scale Burn-up when disconnected |
|
FXAIM04A-DW | Thermocouple inputs: 7 T, R, J, K, E type correspondence -16 - 80mV full scale Burn-down when disconnected |
|
FXAIM04B-UP | Thermocouple inputs: 7 T, R, J, K, E type correspondence -8 - 40mV full scale Burn-up when disconnected |
|
FXAIM04B-DW | Thermocouple inputs: 7 T, R, J, K, E type correspondence -8 - 40mV full scale Burn-down when disconnected |
|
FXAIM04C-UP | Thermocouple inputs: 7 T, R, J, K, E type correspondence -16 - 80mV full scale Burn-up when disconnected AD converter duplicated |
|
FXAIM04C-DW | Thermocouple inputs: 7 T, R, J, K, E type correspondence -16 - 80mV full scale Burn-down when disconnected AD converter duplicated |
|
FXAIM04D-DW | Thermocouple inputs: 7 T, R, J, K, E type correspondence -8 - 40mV full scale Burn-down when disconnected AD converter duplicated |
|
FXAIM05A | Resistance temperature detector (RTD) inputs: 5 RTD type: Pt100 ohm Input range: -100 - 650 deg C |
|
FXAIM05B | Resistance temperature detector (RTD) inputs: 5 RTD type: Pt100 ohm Input range: -40 - 60 deg C |
|
FXAIM05C | Resistance temperature detector (RTD) inputs: 5 RTD type: Pt100 ohm Input range: -100 - 650 deg C AD converter duplicated |
|
FXAIM05E | Resistance temperature detector (RTD) inputs: 5 RTD type: Pt100 ohm Input range: -200 - 200 deg C |
|
FXAIM06A | Resistance temperature detector (RTD) inputs: 5 RTD type: Cu10 ohm (at25 deg C) Input range: 0 - 130 deg C |
|
Analog Output | FXAOM01A | 4 - 20mA / 0 - 20mA outputs: 8 Load resistance: 0 - 550 ohm |
FXAOM01AD | 4 - 20mA / 0 - 20mA outputs: 8 Load resistance: 0 - 550 ohm Duplicated correspondence |
|
FXAOM01B | 4 - 20mA / 0 - 20mA outputs: 4 Load resistance: 0 - 750 ohm |
|
FXAOM01BD | 4 - 20mA / 0 - 20mA outputs: 4 Load resistance: 0 - 750 ohm Duplicated correspondence |